Description
System SINIKON Rain Flow
for internal drainage - drainage of water from all roofs.
Internal gutters are installed inside the heated buildings and provide drainage of rain and meltwater from roofs of residential and industrial buildings.
The main feature of internal drainage is that the drainage risers and drainage pipes must withstand the pressure of the water column that occurs when blockages and overflows of the system. The pressure is determined by the height from the intake hopper to the issue.
Pipe SINIKON Rain Flow
diameter 110 mm
wall thickness of 3.4 mm
The system is designed for the height of the water column (the height of the building from the hopper to the issue) 60 meters.
The absolute reliability of the pipeline at high pressure provided by high requirements for geometrical tolerances in the manufacture of pipes.
It is recommended to use in the draining of the riser piping to roof drains and drain risers with a maximum height of 30 meters.
The pipe is manufactured by extrusion (molding of indefinite length by extrusion of polymer melt through the forming head with the channels of the profile) of the propylene homopolymer (type 1) PP - N. SINIKON Rain Flow 100 on the other 2248-060-42943419-2012 with a nominal diameter of 110 mm and a wall thickness of 5.3 mm, S series pipe 10 in SDR 21, SINIKON Rain Flow on the other 2248-010-42943419-2011.
Fittings Rain Flow (in addition to the transition of PP/steel flange and compression fittings) are designed for use only in drainage pipes to drain funnels.
Working pressure fittings 1 bar (10 m V. S.), maximum 1.5 bar (15 m V. S.).
Use fittings, Rain Flow gutter riser and release is PROHIBITED.
In the water drainage riser and release used compression fittings with a working pressure below 10 bar. These fittings are fully compatible with the pipes 60 and Rain Flow Rain Flow 100. As a revision at the bottom of the riser tee compression use with flange PN10.
Fittings shall be rigidly fixed to prevent longitudinal and transverse movements. If you can't install fasteners in the connecting parts (fittings) neighboring parts fixed with clamps at distances that ensure the elongation of the connecting parts.
Characteristics
- Height of water column
- 60 meters
- Wall thickness
- 3.4 mm
- Diameter
- 110 mm